Asphalt Metering Pump
Asphalt Metering Pump
Today, a client—who works at a research institution—reached out in need of a metering pump equipped with a flow display, intended for the transfer of very small quantities of asphalt.
The specific operational parameters are as follows:
Asphalt flow rate: 80–120 L/h
Pressure: Approximately 0.5–0.7 bar
Asphalt temperature: 90–150°C
Asphalt viscosity (at operating temperature): 300–600 mm²/s. !!! A key challenge here is that the asphalt cools to ambient temperature after each experiment and must be reheated before the next run; consequently, a standard flow meter is not a suitable solution.
The allowable margin of error for flow measurement is approximately +/-3% of the actual flow rate. The client requires the flow rate (in L/h) to be monitored via a display, with a precision of at least two decimal places.
Could you provide any solutions to meet these requirements?
Upon reviewing the inquiry, our technical team recommended our plunger-type metering pump:
Model: J2H120/1.0
Type: Plunger-type metering pump
Flow rate: 120 L/h
Pressure: 1.0 MPa
Connections: DN15 flanged inlet/outlet
Pump head: Fully jacketed for thermal insulation
Motor: 0.75 kW, 4-pole standard motor
Pump head material: 304 stainless steel
Power supply: AC 380V, 50 Hz, 3-phase
If you would like to learn more about industrial or
chemical metering pumps—including specific model selection and pricing—please feel free to contact Winny:
WhatsApp: +86 18049841995