Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.

Industry News

Home > News > Industry News >

Vacuum Gauge for Air & Nitrogen – How One Customer Fixed Their Process Instability

Vacuum Gauge for Air & Nitrogen – How One Customer Fixed Their Process Instability
 
The Customer
A thin-film coating manufacturer was struggling with inconsistent coating thickness across batches. Their existing vacuum gauge gave slow, drifting readings, especially in the 0.1–1000 Pa range — right where their process mattered most.
 
They ran only air and nitrogen through their rough pumping lines, but their gauge was over-engineered for gases they never used, and under-performing where it counted.
 
The Challenge
Issue Impact
Response time too slow Pressure overshoot caused film non-uniformity
Poor repeatability Each batch required re-calibration
Fragile connector pins Frequent downtime for repairs
No power adapter included Delayed installation while sourcing parts
They needed a dedicated vacuum gauge for air and N₂ that was fast, stable, and ready to install the same day.
 
The Solution: CX-PRN12
They installed the CX-PRN12 Vacuum Gauge — specifically designed for air and nitrogen applications.
 
Here‘s how it performed:
 
Requirement CX-PRN12 Delivered
Fast control response <100 ms — pressure stabilized instantly
Consistent readings ±2% repeatability (0.1–1000 Pa) — no more batch drift
Rugged build SS316L + tungsten + Kovar + glass — survived daily cycling
Easy setup 24V DC adapter included — running in 10 minutes
Standard connection DN16 ISO-KF — fit their existing port perfectly
The Result
After 3 months of production:
 
Scrap rate reduced by 6%
 
Zero gauge-related downtime
 
No calibration drift observed between maintenance intervals
 
The production manager commented:
 
"Finally, a vacuum gauge that matches what we actually use — air and nitrogen. No wasted features, just solid readings every time."
 
Quick Specs – CX-PRN12
Parameter Specification
Media Air, N₂ only
Range 1.0×10⁻¹ – 1.0×10⁵ Pa
Accuracy ±15% (0.1–10⁴ Pa); ±50% (10⁴–10⁵ Pa)
Repeatability ±2% (0.1–10³ Pa); ±5% (10³–10⁵ Pa)
Response Time <100 ms
Power +24 VDC / 0.5A (adapter included)
Vacuum Port DN16 ISO-KF (custom options available)
Max Overload 2.0×10⁵ Pa
Material (wetted) SS316L, Tungsten, Kovar, Glass
Who Should Buy This?
Order the CX-PRN12 if your system:
 
Uses only air or nitrogen
 
Operates from 0.1 Pa to atmosphere
 
Needs fast, repeatable pressure data
 
Values plug-and-play installation with standard KF16 fittings



 